Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

Background Several biomarkers for predicting intrauterine growth restriction (IUGR) have been proposed in recent years. However, the predictive performance of these biomarkers has not been systematically evaluated. Objective To determine the predictive accuracy of novel biomarkers for IUGR in women with singleton gestations. Search strategy Electronic databases, reference list checking and conference proceedings. Selection criteria Observational studies that evaluated the accuracy of novel biomarkers proposed for predicting IUGR. Data collection and analysis Data were extracted on characteristics, quality and predictive accuracy from each study to construct 2 × 2 tables. Summary receiver operating characteristic curves, sensitivities, specificities and likelihood ratios (LRs) were generated. Main results A total of 53 studies, including 39 974 women and evaluating 37 novel biomarkers, fulfilled the inclusion criteria. Overall, the predictive accuracy of angiogenic factors for IUGR was minimal (median pooled positive and negative LRs of 1.7, range 1.0-19.8; and 0.8, range 0.0-1.0, respectively). Two small case-control studies reported high predictive values for placental growth factor and angiopoietin-2 only when IUGR was defined as birthweight centile with clinical or pathological evidence of fetal growth restriction. Biomarkers related to endothelial function/oxidative stress, placental protein/hormone, and others such as serum levels of vitamin D, urinary albumin: creatinine ratio, thyroid function tests and metabolomic profile had low predictive accuracy. Conclusions None of the novel biomarkers evaluated in this review are sufficiently accurate to recommend their use as predictors of IUGR in routine clinical practice. However, the use of biomarkers in combination with biophysical parameters and maternal characteristics could be more useful and merits further research. © 2013 The Authors BJOG An International Journal of Obstetrics and Gynaecology © 2013 RCOG.

Original publication

DOI

10.1111/1471-0528.12172

Type

Journal article

Journal

BJOG: An International Journal of Obstetrics and Gynaecology

Publication Date

01/05/2013

Volume

120

Pages

681 - 694