Cookies on this website

We use cookies to ensure that we give you the best experience on our website. If you click 'Accept all cookies' we'll assume that you are happy to receive all cookies and you won't see this message again. If you click 'Reject all non-essential cookies' only necessary cookies providing core functionality such as security, network management, and accessibility will be enabled. Click 'Find out more' for information on how to change your cookie settings.

AbstractObjectivesTo assess the accuracy of ultrasound measurement of the lower uterine segment (LUS) thickness against findings at laparotomy, and to investigate its correlation with the success rate of vaginal birth after one previous caesarean delivery (CD) in a resource‐limited setting.DesignProspective study.SettingObstetrics and Gynaecology department in a tertiary hospital in Ghana.PopulationWomen with one previous CD undergoing either a trial of labour (TOLAC) or elective CD.MethodsMyometrial lower uterine segment thickness (mLUS) and full lower uterine segment thickness (fLUS) were measured with transvaginal ultrasound (TVUS). The women were managed according to local protocols with the clinicians blinded to the ultrasound measurements. The LUS was measured intraoperatively for comparison with ultrasound measurements.Main outcome measuresLower uterine segment findings at laparotomy, successful vaginal birth.ResultsA total of 311 pregnant women with one previous CD were enrolled; 147 women underwent elective CD and 164 women underwent a TOLAC. Of the women that underwent TOLAC, 96 (58.5%) women had a successful vaginal birth. The mLUS was comparable to the intraoperative measurement in the elective CD group with LUS thickness <5 mm (bias of 0.01, 95% CI −0.10 to 0.12 mm) whereas fLUS overestimated LUS <5 mm (bias of 0.93, 95% CI 0.80–1.06 mm). Successful vaginal birth rate correlated with increasing mLUS values (odds ratio 1.30, 95% CI 1.03–1.64). Twelve cases of uterine defect were recorded. LUS measurement ≤2.0 mm was associated with an increased risk of uterine defects with a sensitivity of 91.7% (95% CI 61.5–99.8%) and specificity of 81.8% (95% CI 75.8–86.8%).ConclusionAccurate TVUS measurement of the LUS is technically feasible in a resource‐limited setting. This approach could help in making safer decisions on mode of birth in limited‐resource settings.

Original publication

DOI

10.1111/1471-0528.17872

Type

Journal article

Journal

BJOG: An International Journal of Obstetrics &amp; Gynaecology

Publisher

Wiley

Publication Date

03/06/2024